Robur Line F1 Series Instrukcja Instalacji

Przeglądaj online lub pobierz Instrukcja Instalacji dla Kuchenki Robur Line F1 Series. Robur Line F1 Series Unit installation Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - Installation, use and

Heaters Line F1 Series Gas fired unit heatersfor heating medium-large areasNatural gas/LPG firedInstallation, use and maintenance manual

Strona 2

Ed. 05/2009 User, Installation and Service Manual for F1 Gas Unit Heaters 8 SECTION 3 - INSTALLATION GENERAL RULES WARNING! - A qualified service

Strona 3 - F1 GAS FIRED UNIT HEATERS

User, Installation and Service Manual for F1 Gas Unit Heaters 9Ed. 05/2009 NOTE The electrical safety of the unit is attained only when the unit its

Strona 4

Ed. 05/2009 User, Installation and Service Manual for F1 Gas Unit Heaters 10 Figure 4 POSITION OF THE UNITS SIZE AND INSTALLATION OF THE AIR INLET /

Strona 5 - SECTION 1 - GENERAL WARNINGS

User, Installation and Service Manual for F1 Gas Unit Heaters 11Ed. 05/2009 Note: When horizontal pipes with lengths above 1 metre are installed, t

Strona 6 - CONSTRUCTIVE CHARACTERISTICS

Ed. 05/2009 User, Installation and Service Manual for F1 Gas Unit Heaters 12Mod. Flue Temperature °C Flue flow (weight) kg/h Max. Allowed Pressure

Strona 7

User, Installation and Service Manual for F1 Gas Unit Heaters 13Ed. 05/2009 MAXIMAL PIPE LENGTH BY VARIOUS INSTALLATION Type of Installation B 23

Strona 8 - TECHNICAL CHARACTERISTICS

Ed. 05/2009 User, Installation and Service Manual for F1 Gas Unit Heaters 14FDEACod. P3370A F1 Unit HeaterD Pipe Ø 80E Pipe Ø 80F Coaxial Pi

Strona 9 - DIMENSIONS OF THE UNITS

User, Installation and Service Manual for F1 Gas Unit Heaters 15Ed. 05/2009 Figure 12 WALL TERMINAL POSITION Note: If the total le

Strona 10 - GENERAL RULES

Ed. 05/2009 User, Installation and Service Manual for F1 Gas Unit Heaters 16 SUPPORT BRACKET INSTALLATION Manufacturer supplies an optional, easy-to

Strona 11 - CLEARANCES TO BE RESPECTED

User, Installation and Service Manual for F1 Gas Unit Heaters 17Ed. 05/2009 Note: The control cables (specially those linked to the remote control a

Strona 13 - 2-3 CM PER METER

Ed. 05/2009 User, Installation and Service Manual for F1 Gas Unit Heaters 18 BURNER PRESSURE SETTING TABLE FOR UNITS SUPPLIED WITH LPG (G31) PROPANE

Strona 14 - For each 45

User, Installation and Service Manual for F1 Gas Unit Heaters 19Ed. 05/2009 CONVERSION TO ANOTHER TYPE OF GAS WARNING! Qualified engineers must carr

Strona 15 - Table 4

Ed. 05/2009 User, Installation and Service Manual for F1 Gas Unit Heaters 20 Figure 15 Figure 16 C) Loo

Strona 16

User, Installation and Service Manual for F1 Gas Unit Heaters 21Ed. 05/2009 OPERATING WIRING DIAGRAM Figure 18 LEGEND: M9 fuse

Strona 17 - Engineer or Manufacturer

Ed. 05/2009 User, Installation and Service Manual for F1 Gas Unit Heaters 22INSTALLATION WIRING DIAGRAM Figure 19 INSTALLATION WIRING DIAGRAM OF F

Strona 18 - FRONT VIEW

User, Installation and Service Manual for F1 Gas Unit Heaters 23Ed. 05/2009 WIRING DIAGRAM FOR MULTIPLE UNIT INSTALLATIONS 230 V50 HzGND Figure 20

Strona 19 - Ed. 05/2009

Ed. 05/2009 User, Installation and Service Manual for F1 Gas Unit Heaters 24 P programmatoreTA termostato ambienteRL relè comando programma

Strona 20 - VALVOLA BM 762

User, Installation and Service Manual for F1 Gas Unit Heaters 25Ed. 05/2009 SECTION 4 - USE AND OPERATION START AND STOP OF THE UNIT WARNING Qualif

Strona 21

Ed. 05/2009 User, Installation and Service Manual for F1 Gas Unit Heaters 26 Stop of the unit - To turn off the unit, set the room thermostat to

Strona 22

User, Installation and Service Manual for F1 Gas Unit Heaters 27Ed. 05/2009 SECTION 5 - MAINTENANCE AND SERVICING REMOVABLE BURNER The burner mo

Strona 23

Ed. 05/2009 F1 GAS FIRED UNIT HEATERS TABLE OF CONTENTS SECTION 1 GENERAL WARNINGS: ...

Strona 24 - INSTALLATION WIRING DIAGRAM

Ed. 05/2009 User, Installation and Service Manual for F1 Gas Unit Heaters 28 WARNING Only qualified service engineer authorised by Manufacturer must

Strona 25 - programmato

User, Installation and Service Manual for F1 Gas Unit Heaters 29Ed. 05/2009 thus preventing re-ignition. When electricity returns, push the reset bu

Strona 26 - RL relè comando

Ed. 05/2009 User, Installation and Service Manual for F1 Gas Unit Heaters 30TROUBLESHOOTING FLOW CHART Consult yourinstallerThe heater does notstart

Strona 27 - ☼ for the ventilation

User, Installation and Service Manual for F1 Gas Unit Heaters 31Ed. 05/2009 continued

Strona 28 - THE LIMIT SWITCH

Ed. 05/2009 User, Installation and Service Manual for F1 Gas Unit Heaters 32 With the aim of continuously improving the

Strona 30

Robur is dedicated to dynamic progressionin research, development and promotionof safe, environmentally-friendly, energy-efficiency products,through th

Strona 31

Ed. 05/2009 User, Installation and Service Manual for F1 Gas Unit Heaters 2

Strona 32 - TROUBLESHOOTING FLOW CHART

Installation, Start-Up and Service Manual for F1 Gas Unit Heaters 3Ed. 05/2009 SECTION 1 - GENERAL WARNINGS - This manual is an integral and essen

Strona 33

Ed. 05/2009 User, Installation and Service Manual for F1 Gas Unit Heaters 4 SECTION 2 - GENERALITY AND CHARACTERISTIC OPERATION OF THE UNIT - The

Strona 34

User, Installation and Service Manual for F1 Gas Unit Heaters 5Ed. 05/2009 SAFETY AND CONTROL DEVICES - High temperature limit switch: 100°C with m

Strona 35

Ed. 05/2009 User, Installation and Service Manual for F1 Gas Unit Heaters 6 TECHNICAL CHARACTERISTICS MODEL UNIT F1 21 F1 31 F1 41 F1 51 F1 61

Strona 36 - Robur Mission

User, Installation and Service Manual for F1 Gas Unit Heaters 7Ed. 05/2009 DIMENSIONS OF THE UNITS A B C D E F G H J L N F1 21 630 640

Komentarze do niniejszej Instrukcji

Brak uwag